Mode | Instrument (click for detail) |
Test provided |
Relative AAPM Reference (USA) |
CT Simulation
|
Geocheck1
|
Laser alignment
|
TG 53
|
| |
Couch Indexing
|
TG 53
|
| |
|
|
|
Exradin CT Chamber
|
Dosimetry
|
|
|
MAX 4000 Electrometer
|
Dosimetry
|
|
| |
|
|
|
QUASAR Beam Geometry CT Phantom
|
Multiplanar CT reconstruction
|
TG 53
|
| |
Geometric accuracy
|
TG 53
|
| |
3D measurement tools in software
|
TG 53
|
| |
Beam display graphics at oblique gantry and couch angles
|
TG 53
|
| |
Image transfer, storage and retrieval
|
TG 53
|
| |
DICOM tools on all workstations
|
TG 53
|
| |
2D image accuracy and measurement tools
|
TG 53
|
| |
|
|
|
QUASAR Body CT Phantom
|
Geometric accuracy of 2D images and 3D reconstructions
|
TG 53
|
| |
2D and 3D measurement tools including reconstructions
|
TG 53
|
| |
Boundary identification tools, automatic, semi-automatic, and manual
|
TG 53
|
| |
Automargining tools
|
TG 53
|
| |
Representation and manipulation of contoured patient anatomy
|
TG 53
|
| |
Dose volume histograms
|
TG 53
|
| |
Conversion of CT Numbers to relative electron densities
|
TG 53
|
| |
Comparison of display on CT sims, RTPS and other imaging workstations
|
TG 53
|
| |
Image transfer, storage and retrieval
|
TG 53
|
| |
DICOM tools on all workstations
|
TG 53
|
|
|
|
|
Plan Verification, Dose Verification
|
|
|
|
|
Exradin A14 Ion Chamber
|
Dosimetry
|
|
|
MAX 4000 Electrometer
|
Dosimetry
|
|
|
IMRT Dose Verification Phantom
|
Treatment plan verification in an anthropomorphic setting
|
|
| |
Relative dose in ten locations
|
|
| |
Dose at PTV
|
|
| |
Lung and bone fields for evaluation of edge effects
|
|
| |
Film dosimetry at 3 cm increments
|
|
| |
TDL/Diode/ Mosfet measurements
|
|
|
Virtual Water Plastic, 30 x 30 x 15 cm
|
Relative dose in ten locations
|
|
| |
Film dosimetry at varying increments, down to 0.5 cm
|
|
|
TDL chips and TLD reader
|
Relative dose verification in IMRT Dose Verification Phantom
|
|
|
|
|
|
Film Dosimetry
|
Film Processor
|
|
|
|
Film Processor QA Kit
|
Consistency of film processing
|
TG 4, R60
|
|
Verification, localization film
|
Treatment planning verification
|
|
|
Film Scanner, VXR-16
|
Treatment planning verification
|
|
|
Film Scanning Software
|
Treatment planning verification
|
|
|
|
|
|
Portal Imaging
|
|
|
|
|
QUASAR Beam Geometry CT Phantom
|
Quality of portal images
|
|
| |
Establish benchmarks and baseline data for EPID quality assurance records
|
TG 58, R75
|
| |
Geometric Reproducibility
|
TG 58, R75
|
| |
Digital reconstruction of portal images
|
TG 58, R75
|
| |
Image storage, transfer and retrieval
|
TG 58, R75
|
|
Film Processor QA Kit
|
Consistency of portal film processing
|
TG 28, R24
|
|
|
|
|
Geometric Accuracy of Linear Accelerators
|
|
|
|
|
GeoCheck 1
|
All laser system alignments
|
TG 40, R46
|
|
|
Accuracy of distance indicator
|
TG 40, R46
|
|
|
Linearity of the distance indicator
|
TG 40, R46
|
|
|
Uniformity of distance indicator with gantry rotation
|
TG 40, R46
|
|
|
Collimator size and uniformity
|
TG 40, R46
|
|
|
Angle accuracy of collimator rotation
|
TG 40, R46
|
|
|
Mechanical isocenter at 0-90-270 degrees
|
TG 40, R46
|
|
|
Linear movement of treatment couch
|
TG 40, R46
|
|
|
Rotational movement of treatment couch
|
TG 40, R46
|
|
|
Agreement of optical and geometric isocenter
|
TG 40, R46
|
|
|
Table height indicator
|
TG 40, R46
|