Home Enquiry Form Quotation Request Forms Brochure Request Form What's New Product Lists Product User Manuals Product Technical Notes Ultrasound Equipment Ultrasound Transducers Seeding/Biopsy Steppers Disposable Grids Disposable Drapes Endocavity Balloons Grid Adapters PAL Pro Stirrups OR Tables / Trolleys Source Measurement Electrometers Equipment Services Suggestions FAQ Search Useful Web Sites Training Courses Calibrations and Upgrades Intravascular Brachy LDR Calibrations Prostate Brachytherapy Prostate Biopsy 3D Prostate Mapping Prostate Cancer Prostate Seed Implant Mammography/Diagnostics Site Map External Beam/IMRT/CT Exradin Ion Chambers Prostate Scanning SeeDs and Strands Prostate Seeding Needles Stabilisation Needles LDR,HDR,PDR Dose Planning Ir-192 Seeds in Ribbon HDR Prostate Brachy HDR/LDR Templates AUTIMO Beam Systems Alloys and Alloy Melters Slideshow Bibliography Our Company Urology Biopsy Biopsy Guns/Needles Needles/Guns/Applications Clinical Oncology Needles Haematology Biopsy Interventional Radiology Urology Needles/Guns Breast Biopsy/Localisation Gynae Biopsy / Aspiration Skin Biopsy Punch Anaesthesia Needles Antenatal Diagnostic Needle Guides Syringe Holders Biopsy Grids Biopsy Steppers Infection Control-MultiMAT Bone Marrow Biopsy Vertebroplasty Laparoscopy Needles Laparoscopy Support Temno Adjustable Coaxial MRI Biopsy/Localisation Percutaneous Injection-PIA Portable Bladder Scanner Cryotherapy Brachytherapy Template Guided Biopsy Volume Studies Gold Fiduciary Markers Fiducial Marker Placement Micro-Touch Micro-Touch LP NEW EX3 Stepper Classic Stepper Multi-Purpose Workstation Stabilizers Steppers Brachy/Biopsy Accessories Radiotherapy Immobilization Rehabilitation Fixation
 

 Temno Adjustable Coaxial
Home
Enquiry Form
Quotation Request Forms
Brochure Request Form
What's New
Product Lists
Product User Manuals
Product Technical Notes
Ultrasound Equipment
Ultrasound Transducers
Seeding/Biopsy Steppers
Disposable Grids
Disposable Drapes
Endocavity Balloons
Grid Adapters
PAL Pro Stirrups
OR Tables / Trolleys
Source Measurement
Electrometers
Equipment
Services
Suggestions
FAQ
Search
Useful Web Sites
Training Courses
Calibrations and Upgrades
Intravascular Brachy
LDR Calibrations
Prostate Brachytherapy
Prostate Biopsy
3D Prostate Mapping
Prostate Cancer
Prostate Seed Implant
Mammography/Diagnostics
Site Map
External Beam/IMRT/CT
Exradin Ion Chambers
Prostate Scanning
SeeDs and Strands
Prostate Seeding Needles
Stabilisation Needles
LDR,HDR,PDR Dose Planning
Ir-192 Seeds in Ribbon
HDR Prostate Brachy
HDR/LDR Templates
AUTIMO Beam Systems
Alloys and Alloy Melters
Slideshow
Bibliography
Our Company
Urology Biopsy
Biopsy Guns/Needles
Needles/Guns/Applications
Clinical Oncology Needles
Haematology Biopsy
Interventional Radiology
Urology Needles/Guns
Breast Biopsy/Localisation
Gynae Biopsy / Aspiration
Skin Biopsy Punch
Anaesthesia Needles
Antenatal Diagnostic
Needle Guides
Syringe Holders
Biopsy Grids
Biopsy Steppers
Infection Control-MultiMAT
Bone Marrow Biopsy
Vertebroplasty
Laparoscopy Needles
Laparoscopy Support
Temno Adjustable Coaxial
MRI Biopsy/Localisation
Percutaneous Injection-PIA
Portable Bladder Scanner
Cryotherapy
Brachytherapy
Template Guided Biopsy
Volume Studies
Gold Fiduciary Markers
Fiducial Marker Placement
Micro-Touch
Micro-Touch LP
NEW EX3 Stepper
Classic Stepper
Multi-Purpose Workstation
Stabilizers
Steppers
Brachy/Biopsy Accessories
Radiotherapy Immobilization
Rehabilitation Fixation
 


 




 
 

 

 

 

 

 

 

Temno Adjustable Coaxial Biopsy Needles ( Set TAC )

The following Biopsy Needles are available with Temno Adjustable Coaxial introducer needles ( known as Set TAC ),

Set TAC includes the introducer needle. Please click on the item of interest :

  •   New Multi-Core Set TAC : Automatic, disposable, guillotine type soft tissue biopsy needle with Set TAC ( Temno Adjustable Coaxial ) cannula.
  •   Full-Opty Set TAC : Automatic suction cutting histological biopsy needle with Set TAC ( Temno Adjustable Coaxial ) cannula.
  •   Spring Cut Set TAC : Semi automatic, disposable, guillotine type soft tissue biopsy needle instrument with Set TAC ( Temno Adjustable Coaxial ) cannula.
  •   Colt Set TAC : Automatic, disposable, guillotine type soft tissue biopsy needle instrument with Set TAC ( Temno Adjustable Coaxial ) cannula.

Definitions : Logo : Top Core is available as an option for most Guillotine type, soft tissue, biopsy needles.

Where Top Core is available it is indicated by the logo. Please enquire.

 

Logo: Echonox ultrasound echogenic steel is available for most types of biopsy needles. Where Echonox is available it is indicated by the logo. Please enquire.

MRI Compatible : MR Clear is available on certain types of biopsy needles go to MRI Biopsy

NEW MULTI-CORE® , SeeDOS Codes : MLC : Needle gauges 14,16,18, 20 available, Needle lengths 11,15,20 and 25 cm

Disposable Automatic Soft Tissue Biopsy device. Minimum Order : 1 box of 15

Available in versions : Standard, DC  Detachable Cannula and SET TAC

 

 

SeeDOS Ltd - MultiCore Disposable Automatic Soft Tissue Biopsy Device Brochure.pdf

 

SeeDOS Ltd - MULTICORE Instructions.pdf

 

SeeDOS Ltd - MULTICORE TC, SET-TAC Biopsy Instrument, User Instructions.pdf

 

Disposable Automatic Biopsy Device

MULTI-CORE® is the latest single use biopsy device, which performs the entire biopsy manoeuvre quickly, fully automatic, with precision. Versatile, simple to use and reliable, with  unique ergonomics for cocking and  firing, it represents the “state of the art” among automatic biopsy instruments, to date.

Spring loaded stylet and cannula harvest diagnostic quality specimens with minimal tissue displacement or needle deflection.

MULTI-CORE® can be easily operated with one hand, making it ideal for procedures requiring ultrasound guidance.

The needle, made from the echo reflecting metal alloy ECHONOX®, is entirely visible for its whole length under ultrasound guidance and the procedure is free from any risk for malignant cells seeding.

MULTI-CORE®  is also available with  the exclusive TOP-CORE® notch geometry feature, which delivers tissue cores up to 50% larger than standard competitive needles).

MULTI-CORE® is also available as specific set for CT scanning  as well as with detachable cannula for single-access procedures.

MULTI-CORE® SET TAC ( Temno Coaxial ) is also available as a set.

Our MULTI-CORE SET-TAC release has a unique coaxial system compared to competitive products. The cannula is detachable, whereas competitive products need an introducer needle with a larger diameter. The result with our system is a lower invasivity to the patient and less trauma.

MULTI-CORE MR ( MRI compatible ) is also available on request.

Suction Cutting Histological Biopsy Needles :

Full-Opty Set TAC, SeeDOS Codes : FLP- - - - T ( e.g. FLP1911T ): Needle gauges 19,20,21 and 22 available, Needle lengths 11 and15 cm available.                                

Modified Menghini Biopsy Needle with IFR cell rescue. Particularly suitable for lung Fine Needle Aspiration ( FNA ) biopsy.

Please note : Set FLP - - - -T includes Echonox.

 

       

 

SeeDOS Ltd - FULL OPTY Modified Menghini Biopsy Needle with IFR Cell Rescue - brochure.pdf

 

SeeDOS Ltd - FULL-OPTY Instructions - pdf

FULL-OPTY®
Modified Menghini biopsy needle with IFR® cell rescue

FNAB ( fine needle aspiration biopsy ) procedures, large quantities of cells are lost, captured inside the cannula or the syringe, thus dramatically decreasing diagnostic accuracy of the sample.

Since 1984, with Histo-Cut®, we have substantially decreased this problem making recovery of cells from the cannula possible.

FULL-OPTY® makes full recovery of cells from the syringe possible as well. Among the several features of FULL-OPTY®: ease of use, high reliability and high rate of diagnostic performance, increasing the diagnostic success rate.

  • DOUBLE SAMPLING (cytological and micro-histologic) THROUGH SINGLE PUNCTURE:
    High diagnostic accuracy within hepatic diseases and hepatocarcinoma with cirrosis;
    decrease of risks connected to hemo-coagulation.
  • SAC® ( Stereo Abrasive Cytology ) RECOVERY OF CYTOLOGICAL SAMPLING (*):
    Free from stroma (always present within coring needles) with improved sensibility to
    cytological diagnosis.
  • NO RISK FOR MALIGNANT CELLS SEEDING (caused by standard echo-markers) and FULL ULTRASOUND VISUALIZATION
  • AUTOMATICALLY VACUUM ASSISTED:
    Ergonomic and enhanced ease of use.
  • IFR® ( Internal Flushing Rescue ) CELLS RECOVERY FROM SYRINGE’S LUMEN:
    Recovery of ALL cells usually lost in the procedure: full diagnostic capability.

FULL-OPTY® is available also in specific sets for CT and MRI guided procedure.

Centimetre marks and sliding stopper allow an easy depth placement. Sterile, single-patient use.

GO to BIOPSY Quotation Request Form

Guillotine Type Core Biopsy Needles :

Spring-Cut Set TAC, SeeDOS Codes: SPG- - - - TC ( e.g. SPG1411TC ) and SPG - - - -TC+ ( e.g. SPG 1411TC+ ) : Needle gauges 14,16,18 and 20 gauge available, Needle lengths 11,15 or 20 cm available.

Semi automatic, disposable needle device with handle for tru-cut biopsy. Minimum order : 1 box 20 pcs.

Please note : Set SPG - - - -TC+ includes Top Core and Echonox.

 

          

 

SeeDOS Ltd - SPRING CUT Semiautomatic Soft Tissue Biopsy Needle - brochure - pdf

 

SeeDOS Ltd - Spring Cut and Guided Needle Instructions.pdf

 

SeeDOS Ltd - Spring Cut DC Version Instructions.pdf

 

SeeDOS Ltd - SRING CUT TC-MR SET Versions Instructions.pdf

 

SeeDOS Ltd - SPRING CUT TC , SET-TAC Biopsy Instrument, User Instructions, rev 2 .pdf

SPRING-CUT®  DC ( Detachable Cannula )
Semiautomatic Soft Tissue Biopsy Needle

SPRING-CUT®DC represents the latest generation of semi-automatic guillotine-type biopsy needles.
Its exclusive features single it among all other biopsy devices in the same category.

Features include:

  •  Stylet advance button remains locked during   penetration: simpler manoeuvre, increased safety during the biopsy procedure, enhanced sensitivity upon penetration.
  •  Pre-selectable bioptic throw (5-10-20 mm), adaptable  lesion sampling size.
  •  Stylet completely retractable from the cannula left in situ: control of the adequacy of the specimen, ideal for multiple biopsies (prostate mapping).
  •  Stronger mechanism: reliable cutting of the most compact tissue.
  •  50% more core cross sectional size with Top-Core

Specific product releases for CT-guided procedures (TC) and endo-urologic use (DC) available.

PRING-CUT SET TAC ( Temno Coaxial ) is also available as a set.

Our SPRING-CUT SET-TAC release has a unique coaxial system compared to competitive products. The cannula is detachable, whereas competitive products need an introducer needle with a larger diameter. The result with our system is a lower invasivity to the patient and less trauma.

SPRING-CUT MR ( MRI compatible ) is also available on request.

GO to BIOPSY Quotation Request Form

Colt Set TAC, SeeDOS Codes: CLT - - - - TC ( e.g. CLT1411TC ) and CLT - - - - TC+ ( e.g. CLT1411TC+ ) : Needle gauges 14,16 and 18 gauge available, Needle lengths 11,15 and 20cm available.

Fully automatic disposable gun for tru-cut biopsy.         Minimum order : 1 box 20 pcs.

Please note : Set CLT - - - -TC+ includes Top Core and Echonox.

 

          

 

SeeDOS Ltd - COLT Disposable Automatic Soft Tissue Biopsy Instrument - brochure - pdf

 

SeeDOS Ltd - COLT & Needle Guide AG Instructions.pdf

 

SeeDOS Ltd - COLT DC Version Instructions.pdf

 

SeeDOS Ltd - COLT TC - MR SET Instructions.pdf

COLT® DC ( Detachable Cannula )
Disposable Automatic Soft Tissue Biopsy Instrument

COLT® is a single use, guillotine-type, soft tissue biopsy instrument which performs the entire bioptic manoeuvre quickly, fully automatically with precision.

  •  Versatile, simple to use and reliable, with the unique rapid firing or two-stage firing feature, it represents the state of the art in automatic biopsy instruments.

  •  COLT® can be easily operated with one hand, making it ideal for procedures requiring ultrasound guidance. Sample biopsy core length 20mm.

  •  Stylet completely retractable from the cannula left in situ: ideal for multiple biopsies (prostate mapping).

  •  50% more core cross sectional size with Top-Core

Specific product releases for CT-guided procedures (TC) and for endo-urologic use (DC) available.

Colour coded for easier needle size ( gauge ) determination.

SeeDOS Ltd - COLT Clinical Literature.pdf

GO to BIOPSY Quotation Request Form